kriz Sensors Germany
HIGH TEMPERATURE INDUCTIVE PROXIMITY SENSORS.



...Electrical
              Connections...
 
PNP n.o../..n.c.
 
NPN n.o../..n.c.

INDUCTIVE SENSOR DATA SHEET HT19
Sensor Prefix IN10-30HT-180

  ELECTRICAL SPECIFICATIONS     EN60947-5-2
  SENSOR SIZE M30
  AMBIENT TEMPERATURE RANGE -25../..+180C
  AMPLIFIER Internal
  INSTALLATION Flush
  NOMINAL SENSING DISTANCE (SN) 10mm
  SUPPLY VOLTAGE RANGE 10../..30VDC
  RATED SUPPLY VOLTAGE 24VDC
  OUTPUT CURRENT 150mA
  OUTPUT PNP or NPN Formats
  MAX SUPPLY RIPPLE 15% max
  VOLTAGE DROP (output) ≤ 1.8V
  HYSTERESIS (% of SN) ≤ 15%
  REPEATABILITY (% of SN) < 3%
  NO-LOAD SUPPLY CURRENT ≤ 3mA
  MAX SWITCHING FREQ 200Hz
  EXPOSURE RATING Permanent
  TARGET L.E.D. N/A
  CABLE Silicone
  CONNECTOR VERSION Contact sales
  OUTPUT OVERLOAD PROTECTION Incorporated
  SHORT CIRCUIT PROTECTION Incorporated
  REVERSE POLARITY PROTECTION Incorporated
  EMC Class A
  MECHANICAL SPECIFICATIONS
  ENVIRONMENTAL PROTECTION IP67
  HOUSING MATERIAL 1.4305 St Stl.
  FASTNER TORQUE VALUE 40Nm

OUTPUT OPTIONORDER CODE
'Please quote order code to our sales office'
PNP N.O.IN10-30HT-PS-180
PNP N.C.IN10-30HT-POE-180
NPN N.O.IN10-30HT-NS-180
NPN N.C.IN10-30HT-NOE-180

NOTES DIMENSIONS   'Do not scale'
  • 'LEMO' type connectors can only be fitted to sensors M18 and above.
  • Sensors up to 180C supplied with internal amplifiers.
  • Sensors above 180C designated with EXT in the stock code are supplied with an external in-line amplifier as standard DIN rail mounting version available please contact sales.
  • All sensors supplied with 2Mtrs cable as standard, longer lengths are available contact sales.
NON-FLUSH INSTALLATIONFLUSH INSTALLATION
KRIZ SENSORS | Haydnstrasse  7 | D-58509 | Lüdenscheid | Germany.
Tel +49 (0) 2351 60715 | Fax +49 (0) 2351 62860 | Cell 0171-3510220


site created by AW Design © copyright 2007 KRIZ SENSORS GERMANY.
Last update 19/02/2007